50KWH Battery EVE Celll PACE BMS BESS Home Energy Solution 10 Marla House Free Electricity Bill Solar system
1 Product Application Introduction
1.1 Scope of application
This specification sheet introduces the specifications of a 12kW/43 kWh battery rack . The entire system consists of a battery system , hybrid inverter, fire protection system, temperature control system, and power distribution system , making it suitable for a variety of application scenarios .
System Diagram
1.2 Application Environment Requirements
The normal working environment of the system should meet the following requirements:
- Working environment temperature: -20 ℃ ~55 ℃ .
- Relative humidity ≤ 90% RH, no condensation on live parts.
- Altitude ≤ 2000m. If the altitude exceeds 2000m, the system needs to be derated.
- The air should not contain sand and dust that may affect normal operation, as well as conductive, corrosive, or explosive particles and gases;
- No vibration or shock, vertical tilt ≤ 5°.
- Other areas with extreme temperatures (such as extreme cold or extreme heat) and marine climates (such as islands) are not within the scope of use of this product.
2 Product Features
- Standard modularity, plug and play, flexible capacity configuration;
- Highly integrated, small footprint, and high energy density per unit volume;
- Advanced BMS control system ensures battery safety and maximizes available capacity;
- bidirectional hybrid inverter is compatible with multiple standard communication interfaces such as Ethernet and RS485 , and has high adaptability;
- Equipped with an intelligent cloud platform to realize data monitoring and data analysis throughout the product life cycle;
- Independently develop EMS control system to achieve intelligent energy scheduling and optimal distribution
-
No. type Parameter items Parameter value Remark 1 DC side parameters Battery cell type LFP 3.2V/314Ah 2 Rated capacity 49.008 kWh 3 System Configuration 1P16S* 3PACK Battery pack parallel connection 4 Voltage range 43.2~57.6 V 5 Depth of discharge 90% DOD 6 AC side parameters Rated power 12 kW 7 Rated voltage 120 / 240 V 8 AC access method L1/L2/N/PE 9 Rated grid frequency 50/60 Hz​ 10 Power Factor 0.8 (leading) ~ 0.8 (lagging) 11 Photovoltaic parameters Maximum allowable input power 18 kW p 12 Maximum input current 26 A *3 13 Maximum short-circuit current 39 A 14 Maximum input voltage 1000V 15 MPPT voltage range 150~ 9 50V 16 Starting voltage 180V 17 MPPT number /string number 3/2+2+2 18 System parameters System efficiency ≥85% 0.5 CP 19 Operating temperature -20 ~ 55 ℃​ 20 relative humidity 5%~90%RH No condensation 21 altitude < 20 00m Above derating 22 Protection level IP 20 23 Cooling method Air cooling 24 noise ≤75dB 25 Communication methods Ethernet 26 Dimensions (width*height*depth) 509 * 974 * 8 00 mm 27 weight ≤500kg 28 Cycle life ≥8000 Cycles 80% SOH @ Standard